1.Executive Standard:
PV cable(photovoitaic module cable) refers to original draft made out by PV system cable work team of German Standard Committee(Technical Specification 2PFG1169/08.2007 in Rhein TUV company German).
2.No-haogen PV-Cable Type:
PV1-F: Tinned Flexible Copper Wire No Halogen PO Insulation&Sheath Photovoltaic System Cable.
3. Application
Applied to solar panels for power generation and related components of the wiring, connection,particularly suitable for outdoor . Resistance to sunlight, anti-aging , Using the low smoke halogen-free flame retardant materials, higher grade, more safety .
4.Cable Characteristics
MODEL | PV1-F |
Conductor | Tinned copper wire,class 5 (as per IEC 60228) |
Insulation | No Halogen PO insulation |
Sheath | No Halogen PO sheath |
rated voltage | AC 0.6/1KV |
DC 1.8KV | |
Temperature range | -40°C~+90°C,dry/ humidity |
Max.working temperature of conductor | 120°C |
During short circuit | 200°C |
Standard | EN 2PFG 1169 |
5.PV1-F Structure Parameter
type | Cross Sectional Area(mm2) | Conductor structure( Strand /mm) | diameter(mm) | insulation thickness(mm) | sheat thickness(mm) | cable diameter(mm) | DC resistance at 20°C(Ω/km) |
PV1-F | 1.5 | 48/0.2 | 1.6 | 1.0 | 0.8 | 5.2 | 12.2 |
PV1-F | 2.5 | 77/0.2 | 2.0 | 1.0 | 0.8 | 5.6 | 7.56 |
PV1-F | 4 | 56/0.3 | 2.6 | 1.0 | 0.9 | 6.4 | 4.7 |
PV1-F | 6 | 84/0.3 | 3.2 | 1.0 | 0.9 | 7.0 | 3.11 |
PV1-F | 10 | 77/0.41 | 4.4 | 1.0 | 0.9 | 8.2 | 1.84 |
PV1-F | 16 | 119/0.41 | 5.5 | 1.0 | 1.1 | 9.7 | 1.16 |
PV1-F | 25 | 189/0.41 | 6.5 | 1.2 | 1.2 | 11.3 | 0.734 |
PV1-F | 35 | 244/0.41 | 7.5 | 1.2 | 1.2 | 12.3 | 0.529 |
6.Current Capacity Reference Value
(Ambient Temperture:60°C,Max. Conductor Working Temperature:120°C)
Nom.Area(mm2) | Single core in the air(A) | Single core on the equipmnt surface(A) | Next to equipment(A) |
1.5 | 30 | 29 | 24 |
2.5 | 41 | 39 | 33 |
4 | 55 | 52 | 44 |
6 | 70 | 67 | 57 |
10 | 98 | 93 | 79 |
16 | 132 | 125 | 107 |
25 | 176 | 167 | 142 |
35 | 218 | 207 | 176 |
7.Temperature deviation means conversion factor(as per 60364-5-52)
Ambient Temperature(°C) | Conversion Factor | Ambient Temperature(°C) | Conversion Factor | Ambient Temperature(°C) | Conversion Factor |
≤60 | 1.00 | ≤80 | 0.82 | ≤100 | 0.58 |